CN206737531U - A kind of spring vibration isolation structure for low layer masonry structure building - Google Patents
A kind of spring vibration isolation structure for low layer masonry structure building Download PDFInfo
- Publication number
- CN206737531U CN206737531U CN201720260820.3U CN201720260820U CN206737531U CN 206737531 U CN206737531 U CN 206737531U CN 201720260820 U CN201720260820 U CN 201720260820U CN 206737531 U CN206737531 U CN 206737531U
- Authority
- CN
- China
- Prior art keywords
- reinforced concrete
- vibration isolation
- spring vibration
- low layer
- collar tie
- Prior art date
- Legal status (The legal status is an assumption and is not a legal conclusion. Google has not performed a legal analysis and makes no representation as to the accuracy of the status listed.)
- Active
Links
Landscapes
- Buildings Adapted To Withstand Abnormal External Influences (AREA)
Abstract
The utility model discloses a kind of spring vibration isolation structure for low layer masonry structure building, including reinforced concrete foundation collar tie beam;Reinforced concrete foundation collar tie beam is supported by reinforced concrete structural column in foundation wall;The reinforced concrete supporting beam supported by armored concrete Protection Pier is set above the reinforced concrete foundation collar tie beam, is provided with isolation mounting on the upside of the reinforced concrete foundation collar tie beam below reinforced concrete supporting beam, isolation mounting is spring vibration isolation device;The utility model provides a kind of vibration insulation structure suitable for Low-rise Masonry Building, and structure is novel;Compared to traditional masonry structure building form, the utility model can provide safety guarantee to greatest extent under geological process, and make to repair difficulty after shake and be greatly reduced;The utility model compares rubber support shock insulation, there is greater advantage in durability of product, on isolating affection, not only can also be effectively isolated the vertical motion that surrounding enviroment pass over level of isolation to vibration.
Description
Technical field
It the utility model is related to building damper technical field, specifically a kind of bullet for low layer masonry structure building
Spring vibration insulation structure.
Background technology
Rustic home is built more based on Low-rise Masonry Building, and it is built without strict Aseismic Design, does not also enter
The corresponding standard construction of row and supervision, most even basic constructional columns and collar tie beam all do not have.China is in the world two
The intermediate zone of violent earthquake band, be that earthquake takes place frequently country, more than 6 grades ruinous earthquakes occur 5 ~ 6 times every year on average, 7 grades with
Upper macroseism occurs once for average every 5 years, causes substantial amounts of house collapse and casualties.Wenchuan earthquake causes house collapse within 08 year
Up between more than 70 ten thousand.Therefore in some highlight lines area, destructiveness and collapse wind of these rustic homes in the presence of macroseism
Danger is all very high, and after being subjected to earthquake, the reparation of structural damage is also required to consume substantial amounts of resource and energy.Therefore, research and development are a kind of new
Type rustic home isolation structure, the structural damage under geological process is reduced or even is eliminated, have necessarily to new countryside construction
Meaning.
The content of the invention
The purpose of this utility model is to provide a kind of spring vibration isolation structure for low layer masonry structure building, to solve
The problem of being proposed in above-mentioned background technology.
To achieve the above object, the utility model provides following technical scheme:
A kind of spring vibration isolation structure for low layer masonry structure building, including reinforced concrete foundation collar tie beam;Reinforcing bar mixes
Solidifying earth foundation collar tie beam is supported by reinforced concrete structural column in foundation wall;Set above the reinforced concrete foundation collar tie beam by
The reinforced concrete supporting beam of armored concrete Protection Pier support, on the reinforced concrete foundation collar tie beam below reinforced concrete supporting beam
Side is provided with isolation mounting, and isolation mounting is spring vibration isolation device.
As further program of the utility model:The isolation mounting passes through pre-buried spiral shell with reinforced concrete foundation collar tie beam
Bolt is attached.
As the utility model further scheme:The reinforced concrete foundation collar tie beam size is 370X240 mm.
As the utility model further scheme:The isolation mounting bottom sets constructional column 370X500 mm, construction
Column length 600mm.
As the utility model further scheme:The reinforced concrete supporting beam size is 240X450mm.
As the utility model further scheme:The armored concrete Protection Pier size is 370X500mm.
As the utility model further scheme:3cm rubber blankets, distance are set at the top of the armored concrete Protection Pier
Reinforced concrete supporting beam bottom 3cm.
As the utility model further scheme:Distance should be not less than 80cm to the isolation mounting apex distance from the ground.
Compared with prior art, the beneficial effects of the utility model are:
The utility model provides a kind of vibration insulation structure suitable for Low-rise Masonry Building, and structure is novel;Compared to tradition
Masonry structure building form, the utility model can provide safety guarantee to greatest extent under geological process, and make shake
Difficulty is repaired afterwards to be greatly reduced;The utility model compares rubber support shock insulation, has greater advantage in durability of product, in shock insulation
In effect, not only the vertical motion that surrounding enviroment pass over can also be effectively isolated with level of isolation to vibration.
Brief description of the drawings
Fig. 1 is the building structure schematic diagram for the spring vibration isolation structure of low layer masonry structure building.
Fig. 2 is the structural representation for the spring vibration isolation structure of low layer masonry structure building.
Fig. 3 is the sectional view for the spring vibration isolation structure of low layer masonry structure building.
Fig. 4 be for low layer masonry structure building spring vibration isolation structure specific embodiment room plane figure and every
Shake device layout drawing.
Embodiment
The technical scheme of this patent is described in more detail with reference to embodiment.
Refer to Fig. 1-4, a kind of spring vibration isolation structure for low layer masonry structure building, including reinforced concrete foundation
Collar tie beam 2;Reinforced concrete foundation collar tie beam 2 is supported by reinforced concrete structural column in foundation wall 4;The reinforced concrete foundation
The top of collar tie beam 2 sets the reinforced concrete supporting beam 1 supported by armored concrete Protection Pier 5, the steel of the lower section of reinforced concrete supporting beam 1
The upside of reinforced concrete foundation ring girder 2 is provided with isolation mounting 3;Isolation mounting 3 is spring vibration isolation device;The isolation mounting 3 with
Reinforced concrete foundation collar tie beam is attached by pre-embedded bolt;The size of reinforced concrete foundation collar tie beam 2 is 370X240
mm;The bottom of isolation mounting 3 sets constructional column 370X500 mm, construction column length 600mm;The size of reinforced concrete supporting beam 1
For 240X450mm;The size of armored concrete Protection Pier 5 is 370X500mm;The top of armored concrete Protection Pier 5 is set
3cm rubber blankets, apart from the bottom 3cm of reinforced concrete supporting beam 1;Distance should be not less than 80cm to the apex distance of isolation mounting 3 from the ground.
When not considering the situation of foundation failure, the eaerthquake damage of low layer brick masonry structure building is mainly due to Earth Surface During Earthquakes
Horizontal acceleration is excessive during motion, and because house is smaller natural vibration period, its overall acceleration, which can be considered, is equal to ground acceleration,
The horizontal inertial force in house is larger, and greater level shearing is produced in wall causes wall crazing, between some weak parts such as window
Wall easily forms intersection inclined crack, and the utility model technology, will by setting vibration insulation between foundation structure and superstructure
Ground level vibration is isolated so that the acceleration of incoming superstructure significantly weakens, and is dissipated earthquake motion by damper
The energy of input is from and ensureing superstructure and be not damaged.It is infrastructure structure below isolation mounting, reinforced concrete foundation
Collar tie beam apex distance ground level is 0.58m, and basis can use pile foundation or bar base depending on foundation condition, and infrastructure structure can be considered and ground
The firm body that base soil is in close contact, in geological process, its displacement is equal to place displacement and acceleration with acceleration.Seismic Isolation of Isolation Layer
Single vibration isolator horizontal rigidity is about 4000 ~ 8000KN/m, pre-embedded steel slab, vibration isolator bottom and top on foundation ring girder and joist
Vibration isolator and foundation ring girder and joist are connected by weld seam.After house bottom sets vibration isolator, the overall natural period prolongs
It is long, and in vibration insulation formation rigidity weak floor, geological process, energy is by vibration isolator absorbing and filtering caused by earthquake motion, and passes through
Its inside damper dissipate after, only fraction is delivered in upper building, so as to reduce the generation of earthquake, it is ensured that life and
Property safety;
Using Qingdao rural area from two layers of half houses owed by a citizen of lid(One layer of top loft), floor height 3m, loft floor height highest point
For 3.833m.Outer wall thick 370mm, interior wall thickness 240mm, the long 12m in house, wide 11.8m, vibration insulation arrange 38 vibration isolators altogether, often
Platform vibration isolator horizontal rigidity is 6200KN/m, and vertical rigidity is 7800 KN/m.Room plane figure and vibration isolator arrangement are said as follows
Bright book accompanying drawing 4.
In order to investigate performance of the house in earthquake, it is entered from universal architecture finite element analysis software SAP2000
Row is modeled and calculate and analyzes, and wall and floor are simulated using thin shell element, and material property is derived from existing national standard《Masonry knot
Structure design specification》, beam simulated using frame unit, and vibration isolator uses linearly connected unit simulation, be concerned only with during calculating horizontal X to
The free degree, calculate operating mode and select corralit, In The Area of Qingdao comprising static load analysis and linear time history analysis, seismic wave
Fortification intensity is 7 degree of 0.1g, and seismic wave peak accelerator is adjusted to 240gal. slightly larger than earthquake resistant code requirement(220gal).For
The performance capabilities of contrast shock insulation front-end geometry, calculates two models, and A is isolation structure, B be non-shock insulation conventional structure, leads
Want index result of calculation as follows:
Table A Structures under Earthquake response value
Project model A Model B ratios(B/A)
X is to mode cycle 0.55s 0.073s 0.133
Top acceleration 73gal 206gal 2.822
Bearing relative displacement 0.85mm 0mm 0
Base shear 170KN 1247KN 7.335
Finite element analysis results show:1st, using the low layer house owed by a citizen of isolation scheme, than the low layer house owed by a citizen of non-isolation scheme
Earthquake performance capabilities is more excellent, and the seismic shear of substrate can be greatly reduced, and reduces structural damage degree, it is ensured that structure is pacified
Entirely;2nd, horizontal acceleration is relatively low at vibration isolation house floor, and the security of its property such as furniture, suspension member also more has guarantor inside house
Card.
Utility model works principle:The vibration insulation structure that the utility model technology is used for Low-rise Masonry Building includes steel
Reinforced concrete joist, reinforced concrete foundation collar tie beam, spring vibration isolation device, the reinforcing bar being placed on reinforced concrete foundation collar tie beam
Concrete buttress, reinforced concrete structural column, armored concrete Protection Pier.Spring vibration isolation device is positioned over reinforced concrete construction
On post, while set reinforced concrete foundation collar tie beam that possessive construction post drawknot gets up at the absolute altitude, by crab-bolt by bullet
The steel plate of spring isolation mounting bottom is connected with constructional column, and reinforced concrete supporting beam bears upper wall body and floor weight and is supported on
On spring vibration isolation device, joist transmits horizontal force with spring vibration isolation device by frictional force.Spring vibration isolation device is nearby set
Protection Pier is put, construction wall loses fulcrum and destroyed during avoiding spring failure.It is furnished with damping cylinder inside spring vibration isolation device, with
Decay vibrational energy, reduces acceleration peak value.
The better embodiment of this patent is explained in detail above, but this patent is not limited to above-mentioned embodiment party
Formula, can also be on the premise of this patent objective not be departed from one skilled in the relevant art's possessed knowledge
Make a variety of changes.
Claims (8)
1. a kind of spring vibration isolation structure for low layer masonry structure building, including reinforced concrete foundation collar tie beam;Reinforced concrete
Earth foundation collar tie beam is supported by reinforced concrete structural column in foundation wall;Characterized in that, the reinforced concrete foundation collar tie beam
Top sets the reinforced concrete supporting beam that is supported by armored concrete Protection Pier, the armored concrete below reinforced concrete supporting beam
Isolation mounting is provided with the upside of foundation ring girder, isolation mounting is spring vibration isolation device.
2. as described in claim 1 be used for low layer masonry structure building spring vibration isolation structure, it is characterised in that it is described every
Vibrating device is attached with reinforced concrete foundation collar tie beam by pre-embedded bolt.
3. the spring vibration isolation structure for being used for low layer masonry structure building as described in claim 1, it is characterised in that the steel
Reinforced concrete foundation ring girder size is 370X240 mm.
4. as described in claim 1 be used for low layer masonry structure building spring vibration isolation structure, it is characterised in that it is described every
Vibrating device bottom sets constructional column 370X500 mm, construction column length 600mm.
5. the spring vibration isolation structure for being used for low layer masonry structure building as described in claim 1, it is characterised in that the steel
Reinforced concrete joist size is 240X450mm.
6. the spring vibration isolation structure for being used for low layer masonry structure building as described in claim 1, it is characterised in that the steel
Reinforced concrete Protection Pier size is 370X500mm.
7. the spring vibration isolation structure for being used for low layer masonry structure building as described in claim 1, it is characterised in that the steel
3cm rubber blankets are set at the top of reinforced concrete Protection Pier, apart from reinforced concrete supporting beam bottom 3cm.
8. as described in claim 1 be used for low layer masonry structure building spring vibration isolation structure, it is characterised in that it is described every
Distance should be not less than 80cm to vibrating device apex distance from the ground.
Priority Applications (1)
Application Number | Priority Date | Filing Date | Title |
---|---|---|---|
CN201720260820.3U CN206737531U (en) | 2017-03-17 | 2017-03-17 | A kind of spring vibration isolation structure for low layer masonry structure building |
Applications Claiming Priority (1)
Application Number | Priority Date | Filing Date | Title |
---|---|---|---|
CN201720260820.3U CN206737531U (en) | 2017-03-17 | 2017-03-17 | A kind of spring vibration isolation structure for low layer masonry structure building |
Publications (1)
Publication Number | Publication Date |
---|---|
CN206737531U true CN206737531U (en) | 2017-12-12 |
Family
ID=60556649
Family Applications (1)
Application Number | Title | Priority Date | Filing Date |
---|---|---|---|
CN201720260820.3U Active CN206737531U (en) | 2017-03-17 | 2017-03-17 | A kind of spring vibration isolation structure for low layer masonry structure building |
Country Status (1)
Country | Link |
---|---|
CN (1) | CN206737531U (en) |
Cited By (1)
Publication number | Priority date | Publication date | Assignee | Title |
---|---|---|---|---|
CN108661359A (en) * | 2018-07-23 | 2018-10-16 | 苏州岸肯电子科技有限公司 | A kind of shock-absorbing and noise-eliminating room |
-
2017
- 2017-03-17 CN CN201720260820.3U patent/CN206737531U/en active Active
Cited By (1)
Publication number | Priority date | Publication date | Assignee | Title |
---|---|---|---|---|
CN108661359A (en) * | 2018-07-23 | 2018-10-16 | 苏州岸肯电子科技有限公司 | A kind of shock-absorbing and noise-eliminating room |
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Clemente et al. | Seismically isolated buildings in Italy: State-of-the-art review and applications | |
Branco et al. | Seismic rehabilitation of historical masonry buildings | |
Mayes et al. | Design of structures with seismic isolation | |
Nanda et al. | Suitable friction sliding materials for base isolation of masonry buildings | |
Kogilgeri et al. | A study on behaviour of outrigger system on high rise steel structure by varying outrigger depth | |
Kouris et al. | The L’Aquila Earthquake, April 6th, 2009: A review of seismic damage mechanisms | |
Nakagawa et al. | Collapse behavior of a brick masonry house using a shaking table and numerical simulation based on the extended distinct element method | |
CN206737531U (en) | A kind of spring vibration isolation structure for low layer masonry structure building | |
CN113982013A (en) | Quakeproof foundation structure for building and construction method thereof | |
Xu et al. | Shaking table comparative test and associated study of a stepped wall-frame structure | |
Chougule et al. | Seismic soil structure interaction of buildings with rigid and flexible foundation | |
Ahkam et al. | Seismic behavior of structural models of dual system building and flat slab-drop panel strengthened with shear-wall | |
Julie et al. | Performance of base isolators and tuned mass dampers in vibration control of a multistoried building | |
Smirnov et al. | Seismic isolation of buildings and historical monuments. Recent developments in Russia | |
Mustafaraj et al. | Conditional Assessment of Historical Structures: Earthquake Performance of Naziresha Mosque | |
Piancastelli | Common mistakes and their fixes in earthquake-resistant buildings | |
CN110344457A (en) | A kind of shock resistance ancient architecture foundation ruggedized construction | |
Zanazzi et al. | Masonry spires: 3D models to understand their seismic vulnerability | |
Tallapalem et al. | Analysis of Multi-Storey Building in Different Seismic Zones of India | |
Melkumyan | Latest developments in seismic isolation for civil structures in Armenia | |
Melkumyan | Innovative Seismic Isolation Technologies and New Structural Solutions Developed in Armenia for Construction of New and Retrofitting of Existing Buildings | |
Yashaswini et al. | Comparative Study on Static and Dynamic Analysis of Multistoried Building Using ETABS | |
Pradhan et al. | Seismic vulnerability of Buddhist monasteries: Evidences from the 2011 Sikkim earthquake and dynamic analyses | |
CHANDRAKALA | COMPARISION OF G+ 12 RESIDENTIAL BUILDING WITH AND WITHOUT SHEARWALL USING ETABS A MINI PROJECT REPORT SUBMITTED IN PARTIAL FULFILLMENT OF THE REQUIREMENT | |
Saitta et al. | Seismic analysis and retrofit of a mid-rise building |
Legal Events
Date | Code | Title | Description |
---|---|---|---|
GR01 | Patent grant | ||
GR01 | Patent grant |